Signed in as:
filler@godaddy.com
We are Expecting Quantity Orders, we Provide Global Delivery.
Technical specifications Display Screen Type: High resolution display Screen Size: 7 inches(1 7.7 cm) diagonally Sweep Speed: 25mm/sec Information: Heart Rate, Lead/Pads, Alarm On/Off, Sp02, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy Defibrillator Waveform: Biphasic Energy Display: Moni tor display indicates both selected and delivered energy Charge Prompt Type: Voice and visual prompts Electrode Impedance Measurement Range: 0 250 0hms AED Mode AED Function: Auto analyze and charge x3 with programmable auto energy level selection, sc reen prompts, and voice prompts Shockable Rhythms: Ventricular fibrillation , Ventricular tachycardia , QRS complex wave duration Charge Control: Control on device front panel, press key on paddle Manual Mode Energy Selection: Selectable at 2, 5, 7, 10, 2 0, 30, 50, 70, 100, 150, 200, 300, 360 joules Synchronized Mode: Synchronizes defibrillator pulse to patient's R wave. "SYNC" message displayed on monitor ECG Monitoring Patient Connection: 3 lead ECG cable, or 5 lead ECG cable, paddles Lead Selection : Displayed on monitor, paddles, l, lI, lIl, AVR, AVL, AVF, V ECG Size: 0.25, 0.5, 1 , 1 .5, 2, 4 cm/mV di s play on monitor. Heart Rate: 20 300BPM Heart Rate Alarm: On/Off displayed on monitor, user selectable Smart Alarms: Beeper /V oice prompts indicate s hockable r hythm Sp02 Module Measurement Range: 30 100% , + 2% between 80% 90%, others + 5% Alarm Range: User set high limit and low limit Alarm Accuracy: + 10% within setting values Alarm Time Accuracy: Less than 12 sec Recorder Paper: 50mm thermal Spe ed: 12.5mm/sec, 25mm/sec, 50mm/sec. User selectable 6 second delay Printing Method: High resolution, thermal array print head Print out Modes: Manual or automatic, user configurable On/Off Control: Front panel and paddle Automatic Function: 9 second record ing initiated by alarm activation or defibrillator charge or defibrillator discharge Battary Type: Rechargeable, Ni MH battery, 12V Operating Time: For a new, fully charged battery 60 defibrillator discharges at maximum energy, or 3 hours minimum of con tinuous ECG monitoring. Additional parameters will effect operating time with different functions.
Technical specifications Defibrillator - Defibrillator type Manual, Synchronized, Asynchronized, - Out put waveform Monophasic technology - Energy accuracy <+1% - Energy selection 0,3,5,7,10,20,30,50,100,200,300,360 J oule (nominal at a resistance of - Charging time Maximum 8 seconds to 360 Joules - Standard Adult/Pediatric Paddles Reusable external adu lt paddles (pediatric paddles integrated) . Power requirements - AC Power supply 110V, 60 Hz /220V,50 Hz - Vehicle Voltage DC 12V Internal Battery Backup - Battery type Rechargeable lead acid battery/ lithium battery(optional) - Charging time Time Minimum of 4 hours for full charging - Battery charging During AC Power Supply operation of the device. - Charging /Low Battery Indication Red LED - Battery Capacity 100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 joules. Display - LED Dimensions 7’diagonal {155mm*88mm} - Type High resolution true color graphic LED - Resolution 480X234 ECG ECG lead: I , II , III , AVR, AVL, AVF, V1 V6, GND S T segment analysis: 2.0 2.0mv Arrhythmia analysis: yes Protection With stand 4000vAc/50Hz voltage in isolation and work against eletrosurgical interfere and defibrillation Respiration Measurement method: Thoracic impedance Standard parameter & configuration ECG/ RESP/DE FIBRILLATOR Optional Recorder
Copyright © 2022 TRUTHBIOMEDICAL (OPC) PRIVATE LIMITED ,INDIA & TRUTH BIOMEDICAL LIMITED , United kingdom - All Rights Reserved.
TRUTHBIOMEDICAL (OPC) Private Limited
This website uses cookies. By continuing to use this site, you accept our use of cookies.